Fractures of the proximal humerus involving the intertubercular groove.
Аннотация
The purpose of this study was to analyse the involvement of the gliding surface of the biceps tendon in fractures of the proximal humerus. Fifteen patients had a fracture of the proximal humerus verified with antero-posterior and axillary radiographs. Tangential radiographs of the intertubercular groove, obtained from the shoulder joint, showed involvement of the intertubercular groove in 13 patients (87%), which could not be shown with other projections. Groove radiographs revealed in 3 patients a dislocation of the fragments of the greater tuberosity large enough to require surgical treatment, but which had not been found using conventional techniques. Therefore, a groove radiograph should be used to precise fractures of the proximal humerus.