MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ftd.0000000000000674

Медицинская библиотека · Therapeutic drug monitoring · 2020

A Sensitive LC-MS/MS Assay for the Quantification of Methadone and its Metabolites in Dried Blood Spots: Comparison With Plasma.

Davari Baharak, Kotecha Nidhi, Clavijo Claudia F, Thomas James J, Rzasa-Lynn Rachael, Galinkin Jeffrey L, Christians Uwe, Sempio Cristina

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Methadone, a synthetic narcotic, is widely used both in adults and children for pain control and as a replacement drug in opioid use disorder to prevent craving and withdrawal. To support clinical pharmacokinetic trials in neonates, infants, and children, the authors developed and validated a novel, automated, highly sensitive liquid chromatography-electrospray-tandem mass spectrometry ionization (LC-ESI-MS/MS) method for the quantification of methadone and its metabolites, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenylpyraline (EMDP), in samples collected as dried blood spots.

METHODS

Blood was spiked with different concentrations of methadone, EDDP, and EMDP, and blood drops were applied to filter paper cards. Punches of 6.4 mm were removed from the cards, and 600 µL of protein precipitation solution (methanol/0.2M ZnSO4, 7:3, vol/vol) containing the internal standards (methadone-d9 and EDDP-d5) at a concentration of 1 mcg/L was added. The extracts were analyzed using LC-ESI-MS/MS in combination with online extraction. The mass spectrometer was run in the positive multiple reaction monitoring mode, and the total run time was 3.2 minutes.

RESULTS

For the dried blood spots, the assay has a lower limit of quantification of 0.1 mcg/L for methadone, EDDP, and EMDP. The range of reliable response for methadone for the ion transition m/z = 310.2→265.1 was 0.1-100 mcg/L and for the ion transition m/z = 310.2→223.1 5-1000 mcg/L. For EDDP, on the range of reliable response for the ion transition, m/z = 278.2→234.3 was 0.1-100 mcg/L and for the ion transition m/z = 278.2→186.1 5-1000 mcg/L. The calibration range for EMDP was 0.1-100 mcg/L. Accuracy (85%-115%) and imprecision (<15%) met predefined acceptance criteria.

DISCUSSION: This assay allows for the measurement of small volume blood samples without the need for an intravenous blood draw, and thus, it is suitable for pharmacokinetics studies and therapeutic drug monitoring in pediatric patients.

Для цитирования: Davari Baharak, Kotecha Nidhi, Clavijo Claudia F, Thomas James J, Rzasa-Lynn Rachael, Galinkin Jeffrey L, Christians Uwe, Sempio Cristina. A Sensitive LC-MS/MS Assay for the Quantification of Methadone and its Metabolites in Dried Blood Spots: Comparison With Plasma.. Therapeutic drug monitoring. 2020. DOI: 10.1097/ftd.0000000000000674.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.