Non-invasive assessment of renal allograft fibrosis by dynamic sonographic tissue perfusion measurement.

Syversveen Trygve, Brabrand Knut, Midtvedt Karsten, Strøm Erik H, Hartmann Anders, Berstad Audun Elnaes

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Chronic allograft nephropathy (CAN) characterized by interstitial fibrosis and tubular atrophy is a major cause of renal transplant failure. The diagnosis can currently only be verified by a graft biopsy.

PURPOSE: To evaluate whether non-invasive dynamic color Doppler sonographic parenchymal perfusion measurements are different in grafts with various degrees of biopsy proven renal transplant fibrosis.

MATERIAL AND

METHODS

Forty-nine adult patients were prospectively included. Four patients were excluded. Color Doppler videos from the renal cortex were recorded. Perfusion in the renal cortex was evaluated using a software package which calculates color pixel area and flow velocity, encoded by each pixel inside a region of interest of a video sequence. The software calculates parameters that describe tissue perfusion numerically. Two of these, the perfusion intensity and tissue pulsatility index, were compared to grade of interstitial fibrosis (0-3) in biopsies. Observer agreement was evaluated in a subset of 12 patients.

RESULTS

Of the 45 patients analyzed, 18 patients had grade 0, 18 had grade 1, seven had grade 2 and two had grade 3 fibrosis. The mean perfusion intensity of grade 0 was significantly higher than that of grade 2 and 3 fibrosis in the proximal cortical layer (1.65 m/s vs. 0.84 m/s, P = 0.008). No significant difference was found between grade 0 and grade 1 fibrosis. Perfusion intensity was correlated to estimated glomerular filtration rate (Pearson r 0.51, P = 0.001, R(2) = 0.26 and 0.46, P = 0.001, R(2) = 0.22 in the distal and proximal cortex, respectively). Inter-observer agreement of the perfusion intensity, expressed as intraclass correlation coefficient was 0.69 in the proximal part of the cortex. Intra-observer agreement was 0.85 for observer 1 and 0.82 for observer 2.

CONCLUSION

Perfusion intensity assessed by dynamic color Doppler measurements is significantly reduced in allografts with grade 2 and 3 fibrosis compared to allografts without fibrosis. Further studies involving longitudinal assessment of allografts undergoing protocol biopsies would be of interest.

Для цитирования: Syversveen Trygve, Brabrand Knut, Midtvedt Karsten, Strøm Erik H, Hartmann Anders, Berstad Audun Elnaes. Non-invasive assessment of renal allograft fibrosis by dynamic sonographic tissue perfusion measurement.. Acta radiologica (Stockholm, Sweden : 1987). 2011. DOI: 10.1258/ar.2011.110215.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.