MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0b013e3182155e70

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2011

Short-term in vivo preclinical biocompatibility evaluation of FW-II axial blood pump in a sheep model.

Chen Haibo, Zhou Jianye, Sun Hansong, Tang Yue, Zhang Yan, Liu Guangmao, Hu Shengshou

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We investigated the outcome of FW-II axial pump on healthy sheep (weight, 60-70 kg) for 2 weeks by perioperatively hematological and chemical tests, and circulating activated platelet and leukocyte-platelet aggregates measurements by flow cytometry assays. Complete necropsy and histopathological examinations and thorough pump inspection were performed at study termination for evidence of thrombi. In this experimental series, one sheep died of pulmonary edema, the other four sheep reached the scheduled endpoint of 14 days without device-related problems, and flow range was maintained at 2.5-4.0 L/min. The number of red blood cells and platelets decreased within first 3 days but increased gradually after the first postoperative week. In all animals, serum glutamic oxaloacetic transaminase increased significantly after surgery but gradually returned to normal limits within 2 weeks. Platelet activation, granulocyte-platelet aggregates, and monocyte-platelet aggregates reached the peak at postoperative day 2. Postexplant examinations indicated round thrombus in the hub areas of pumps. No evidence of ischemia or infarction was found in the explanted hearts, livers, spleens, kidneys, and brains of the five animals. Our results demonstrate that FW-II ventricular assist device (VAD) is a promising device for left ventricular (LV) support with moderate anticoagulation.

Для цитирования: Chen Haibo, Zhou Jianye, Sun Hansong, Tang Yue, Zhang Yan, Liu Guangmao, Hu Shengshou. Short-term in vivo preclinical biocompatibility evaluation of FW-II axial blood pump in a sheep model.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2011. DOI: 10.1097/mat.0b013e3182155e70.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.