MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bdr2.2133

Медицинская библиотека · Birth defects research · 2022

The quality and the accuracy of codes for terminations of pregnancy for fetal anomalies recorded in hospital databases in three countries in northern Europe.

Garne Ester, Urhoj Stine Kjaer, Bakker Marian, Gissler Mika, Given Joanne, Heino Anna, Limb Elisabeth, Loane Maria, de Walle Hermien, Morris Joan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The number of terminations of pregnancy for fetal anomalies in Europe (TOPFA) has increased over recent decades. Therefore, it is important that TOPFAs, in addition to all other birth outcomes, are included in the surveillance of congenital anomalies and in studies on possible teratogenic risks of pregnancy exposures. The aim of this study was to evaluate the quality and the accuracy of codes identifying TOPFA cases in hospital databases.

METHODS

TOPFA cases recorded in three EUROCAT congenital anomaly registries (Finland, 2010-2014; Funen in Denmark, 2005-2014; and northern Netherlands, 2013-2014) were linked to hospital databases using maternal IDs.

RESULTS

A total of 2,114 TOPFA cases over the study period were identified in the registries and 2,096 (99%) of these pregnancies were identified in the hospital databases. An end of pregnancy code was present for 91% of the cases and a code for a congenital anomaly was present for 82% (with some differences across registries). The proportion of TOPFA cases with a code for a specific congenital anomaly was <50% for cases with a structural anomaly (range 0%-50%) and 70% for cases with a chromosomal anomaly.

CONCLUSION

Hospital databases have limited information or codes to identify TOPFAs for specific anomalies and the data are not detailed enough for surveillance of congenital anomalies or for studies analyzing pregnancy exposures and risk of congenital anomalies. However, hospital data may be used to identify the occurrence of a TOPFA to enable more detailed information to be obtained from the medical records.

Для цитирования: Garne Ester, Urhoj Stine Kjaer, Bakker Marian, Gissler Mika, Given Joanne, Heino Anna, Limb Elisabeth, Loane Maria, de Walle Hermien, Morris Joan. The quality and the accuracy of codes for terminations of pregnancy for fetal anomalies recorded in hospital databases in three countries in northern Europe.. Birth defects research. 2022. DOI: 10.1002/bdr2.2133.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.