MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2016.09.001

Медицинская библиотека · European journal of radiology · 2016

Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose4™.

Laqmani Azien, Avanesov Maxim, Butscheidt Sebastian, Kurfürst Maximilian, Sehner Susanne, Schmidt-Holtz Jakob, Derlin Thorsten, Behzadi Cyrus, Nagel Hans D, Adam Gerhard, Regier Marc

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare both image quality and visibility of normal and abnormal findings at submillisievert chest CT (smSv-CT) using filtered back projection (FBP) and the two different iterative reconstruction (IR) techniques iterative model reconstruction (IMR) and iDose4™.

MATERIALS AND

METHODS

This institutional review board approved study was based on retrospective interpretation of clinically indicated acquired data. The requirement to obtain informed consent was waived. 81 patients with suspected pneumonia underwent smSv-CT (Brilliance iCT, Philips Healthcare; mean effective dose: 0.86±0.2mSv). Data were reconstructed using FBP and two different IR techniques iDose4™ and IMR (Philips Healthcare) at various iteration levels. Objective image noise (OIN) was measured. Two experienced readers independently assessed all images for image noise, image appearance and visibility of normal anatomic and abnormal findings. A random intercept model was used for statistical analysis.

RESULTS

Compared to FBP and iDose4™, IMR reduced OIN up to 88% and 72%, respectively (p<0.001). A mild blotchy image appearance was seen in IMR images, affecting diagnostic confidence. iDose4™ images provided satisfactory to good image quality for visibility of normal and abnormal findings and were superior to FBP (p<0.001). IMR images were significantly inferior for visibility of normal structures compared to iDose4™, while being superior for visibility of abnormal findings except for reticular pattern (p<0.001).

CONCLUSION

IMR results for visibility of normal and abnormal lung findings are heterogeneous, indicating that IMR may not represent a priority technique for clinical routine. iDose4™ represents a suitable method for evaluation of lung tissue at submillisievert chest CT.

Для цитирования: Laqmani Azien, Avanesov Maxim, Butscheidt Sebastian, Kurfürst Maximilian, Sehner Susanne, Schmidt-Holtz Jakob, Derlin Thorsten, Behzadi Cyrus, Nagel Hans D, Adam Gerhard, Regier Marc. Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose4™.. European journal of radiology. 2016. DOI: 10.1016/j.ejrad.2016.09.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.