Hybrid surgery for blunt aortic injury with rupture: a case report.

Maruhashi Takaaki, Maruki Hideo, Mishima Toshiaki, Kitamura Tadashi, Kurihara Yutaro, Oi Marina, Kataoka Yuichi, Miyaji Kagami, Asari Yasushi

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Blunt thoracic aortic injury is one of the most lethal traumatic injuries. Ruptured cases often result in cardiac arrest before arrival at the hospital, and survival is rare.

CASE PRESENTATION: A female patient in her 30 s was struck by an automobile while she was walking across an intersection. She was in a state of shock when emergency services arrived and was in cardiac arrest shortly after arriving at the hospital. A left anterolateral thoracotomy revealed a massive hemothorax secondary to thoracic aortic rupture. In addition, the patient had multiple traumas, including maxillary, pelvic, and lumbar burst fractures. We attempted to directly suture the aortic lesion; however, the increasing blood pressure caused the suture to break. We used a thoracic stent graft while ensuring permissive hypotension. Her postoperative prognosis was positive, and she was transferred to another hospital 85 days later.

CONCLUSIONS

We successfully performed a hybrid surgery combining thoracotomy and endovascular repair for this emergency case of blunt thoracic aortic injury with rupture.

Для цитирования: Maruhashi Takaaki, Maruki Hideo, Mishima Toshiaki, Kitamura Tadashi, Kurihara Yutaro, Oi Marina, Kataoka Yuichi, Miyaji Kagami, Asari Yasushi. Hybrid surgery for blunt aortic injury with rupture: a case report.. Journal of cardiothoracic surgery. 2022. DOI: 10.1186/s13019-022-02060-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.