MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/rpor.100387

Медицинская библиотека · Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024

Optimized target delineation procedure for the radiosurgery treatment of ventricular tachycardia: observer-independent accuracy.

Hecko Jan, Knybel Lukas, Rybar Marian, Penhaker Marek, Jiravsky Otakar, Neuwirth Radek, Sramko Marek, Haskova Jana, Kautzner Josef, Cvek Jakub

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Part of the current stereotactic arrythmia radioablation (STAR) workflow is transfer of findings from the electroanatomic mapping (EAM) to computed tomography (CT). Here, we analyzed inter- and intraobserver variation in a modified EAM-CT registration using automatic registration algorithms designed to yield higher robustness.

MATERIALS AND

METHODS

This work is based on data of 10 patients who had previously undergone STAR. Two observers participated in this study: (1) an electrophysiologist technician (cardiology) with substatial experience in EAM-CT merge, and (2) a clinical engineer (radiotherapy) with minimum experience with EAM-CT merge. EAM-CT merge consists of 3 main steps: segmentation of left ventricle from CT (CT LV), registration of the CT LV and EAM, clinical target volume (CTV) delineation from EAM specific points. Mean Hausdorff distance (MHD), Dice Similarity Coefficient (DSC) and absolute difference in Center of Gravity (CoG) were used to assess intra/interobserver variability.

RESULTS

Intraobserver variability: The mean DSC and MHD for 3 CT LVs altogether was 0.92 ± 0.01 and 1.49 ± 0.23 mm. The mean DSC and MHD for 3 CTVs altogether was 0,82 ± 0,06 and 0,71 ± 0,22 mm. Interobserver variability: Segmented CT LVs showed great similarity (mean DSC of 0,91 ± 0,01, MHD of 1,86 ± 0,47 mm). The mean DSC comparing CTVs from both observers was 0,81 ± 0,11 and MHD was 0,87 ± 0,45 mm.

CONCLUSIONS

The high interobserver similarity of segmented LVs and delineated CTVs confirmed the robustness of the proposed method. Even an inexperienced user can perform a precise EAM-CT merge following workflow instructions.

Для цитирования: Hecko Jan, Knybel Lukas, Rybar Marian, Penhaker Marek, Jiravsky Otakar, Neuwirth Radek, Sramko Marek, Haskova Jana, Kautzner Josef, Cvek Jakub. Optimized target delineation procedure for the radiosurgery treatment of ventricular tachycardia: observer-independent accuracy.. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. 2024. DOI: 10.5603/rpor.100387.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.