Diagnostic accuracy of CT angiography in infants with tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries.

Meinel Felix G, Huda Walter, Schoepf U Joseph, Rao Anil G, Cho Young Jun, Baker G Hamilton, Hlavacek Anthony M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

CT angiography (CTA) is increasingly used for the evaluation of congenital heart disease.

OBJECTIVE

The aim was to determine the diagnostic accuracy of CTA in infants with tetralogy of Fallot with pulmonary atresia (ToF-PA) and major aortopulmonary collateral arteries (MAPCAs).

METHODS

We retrospectively evaluated 18 consecutive patients (7 girls; median age, 6 days; range, 1-334 days) with ToF-PA and MAPCAs. Findings on CTA were compared with diagnostic catheterization (n = 16) or intraoperative findings (n = 2) for the number of MAPCAs, their diameter, origin, and supplied lung lobes and for the presence and diameter of central pulmonary arteries. Spearman correlation coefficient was calculated to assess the correlation between diameter measurements on CTA and catheterization. CTA dose-length product and catheterization dose-area product were recorded, and effective radiation doses were calculated with the use of age-specific conversion factors.

RESULTS

Agreement was found between CTA and catheterization or intraoperative findings for the number of MAPCAs, their origin, and supplied lung lobes in all cases. In 11 of 13 patients, CTA accurately demonstrated central pulmonary arteries. A good correlation was found between diameter measurements on CTA and catheterization for MAPCAs (r = 0.83) and central pulmonary arteries (r = 0.82). Median effective doses were 0.9 mSv for CTA and 14.4 mSv for catheterization (P < .001).

CONCLUSION

CTA is accurate in the preoperative evaluation of infants with ToF-PA and MAPCAs and is associated with a substantially lower radiation dose than catheterization. Preoperative diagnostic catheterization, therefore, may only be necessary in select patients with small MAPCAs in whom the precise assessment of central pulmonary arteries is required for surgical planning.

Для цитирования: Meinel Felix G, Huda Walter, Schoepf U Joseph, Rao Anil G, Cho Young Jun, Baker G Hamilton, Hlavacek Anthony M. Diagnostic accuracy of CT angiography in infants with tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries.. Journal of cardiovascular computed tomography. 2013. DOI: 10.1016/j.jcct.2013.11.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.