MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1532/hsf98.20121131

Медицинская библиотека · The heart surgery forum · 2013

Device size for transcatheter closure of ovoid interatrial septal defect.

Cho Eun Hyun, Song Jinyoung, Choi Eun Young, Lee Sang Yoon

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

For successful transcatheter closure of an atrial septal defect with the Amplatzer septal occluder, the shape of the defect should be considered before selecting the device size. The purpose of this study was to evaluate the results of transcatheter closure of an ovoid atrial septal defect.

METHODS

Between January 2010 and February 2012, cardiac computer tomography examinations were performed in 78 patients who subsequently underwent transcatheter closure of an atrial septal defect. In this retrospective study, we reviewed these patients' medical records. We defined an ovoid atrial septal defect as a value of 0.75 for the ratio of the shortest diameter of the defect to the longest diameter, as measured in a computed tomography image. Transthoracic echocardiography examinations were made at 1 day and 6 months after the procedure.

RESULTS

Transcatheter closure of an atrial septal defect was successful in 26 patients in the ovoid-defect group and in 52 patients in the round-defect group. There were no serious complications in either group, and the rate of complete closure at 6 months was 92.3% in the ovoid-defect group and 93.1% in the round-defect group (P > .05). The mean (SD) difference between the device size and the defect's longest diameter, and the mean ratio of the device size to the longest diameter were significantly smaller in the ovoid-defect group (1.7 ± 2.9 versus 3.8 ± 2.5 and 1.1 ± 0.1 versus 1.3 ± 0.2, respectively).

CONCLUSIONS

Transcatheter closure of an atrial septal defect is indicated even for an ovoid atrial septal defect. Ovoid atrial septal defects can be closed successfully with smaller sizes of the Amplatzer septal occluder than for round atrial septal defects.

Для цитирования: Cho Eun Hyun, Song Jinyoung, Choi Eun Young, Lee Sang Yoon. Device size for transcatheter closure of ovoid interatrial septal defect.. The heart surgery forum. 2013. DOI: 10.1532/hsf98.20121131.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.