m+Medelevator.RU
← Поиск публикаций
The Journal of dermatology · 2011

Applicability of radiocolloids, blue dyes and fluorescent indocyanine green to sentinel node biopsy in melanoma.

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Uhara Hisashi, Yamazaki Naoya, Takata Minoru, Inoue Yuji, Sakakibara Akihiro, Nakamura Yasuhiro, Suehiro Keisuke, Yamamoto Akifumi, Kamo Riei, Mochida Kosuke, Takenaka Hideya, Yamashita Toshiharu, Takenouchi Tatsuya, Yoshikawa Shusuke, Takahashi Akira, Uehara Jiro, Kawai Mikio, Iwata Hiroaki, Kadono Takafumi, Kai Yoshitaka, Watanabe Shoichi, Murata Satoru, Ikeda Tetsuya, Fukamizu Hidekazu, Tanaka Toshihiro, Hatta Naohito, Saida Toshiaki

Аннотация

Patients with primary cutaneous melanoma underwent sentinel node (SN) mapping and biopsy at 25 facilities in Japan by the combination of radiocolloid with gamma probe and dye. Technetium-99m ((99m)Tc)-tin colloid, (99m)Tc-phytate, 2% patent blue violet (PBV) and 0.4% indigo carmine were used as tracers. In some hospitals, 0.5% fluorescent indocyanine green, which allows visualization of the SN with an infrared camera, was concomitantly used and examined. A total of 673 patients were enrolled, and 562 cases were eligible. The detection rates of SN were 95.5% (147/154) with the combination of tin colloid and PBV, 98.9% (368/372) with the combination of phytate and PBV, and 97.2% (35/36) with the combination of tin colloid or phytate and indigo carmine. SN was not detected in 12 cases by the combination method, and the primary tumor was in the head and neck in six of those 12 cases. In eight of 526 cases (1.5%), SN was detected by PBV but not by radiocolloid. There were 13 cases (2.5%) in which SN was detected by radiocolloid but not by PBV. In 18 of 36 cases (50%), SN was detected by radiocolloid but not by indigo carmine. Concomitantly used fluorescent indocyanine green detected SN in all of 67 cases. Interference with transcutaneous oximetry by PVB was observed in some cases, although it caused no clinical trouble. Allergic reactions were not reported with any of the tracers. (99m)Tc-tin colloid, (99m)Tc-phytate, PBV and indocyanine green are useful tracers for SN mapping.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты