DOI 10.1016/j.jviromet.2026.115436
Performance comparison of rapid and native barcoding methods for Oxford Nanopore sequencing of Poliovirus Viral Protein 1 (VP1) amplicons.
Аннотация
Accurate and timely sequencing of poliovirus is critical for global eradication efforts, particularly for molecular epidemiology based on the typing region of the genome, viral protein 1 (VP1). While Oxford Nanopore Technologies (ONT) sequencing has expanded capabilities for poliovirus surveillance, the relative performance of different ONT library preparation methods, including ligation-based (Native Barcoding) and transposase-based (Rapid Barcoding) approaches, has not been systematically evaluated. In this study, we compared rapid barcoding and native barcoding workflows for sequencing VP1 amplicons from 17 type 2 poliovirus-positive samples, each processed in triplicate. Native barcoding generated significantly more sequencing output, producing approximately 2.3-fold greater total read yield than rapid barcoding, and demonstrated higher run-to-run reproducibility (R2 = 0.979-0.998 vs. 0.847-0.929, respectively; p < 0.001). In addition, native barcoding generated 80% of the total yield achieved by rapid barcoding within approximately 7 h, whereas rapid barcoding required approximately 40 h to reach the same output. Despite these differences, both methods produced identical VP1 consensus sequences across all samples, with comparable read quality (median per-base Q-scores of approximately Q17-Q18). Rapid barcoding provided substantial practical advantages, reducing hands-on library preparation time (55 vs. 200 min) and per-sample cost ($12.82 vs. $16.54), while simplifying workflow and reducing technical complexity. These findings indicate that sequencing yield may not be a determinant of downstream analytical outcomes for poliovirus VP1 ONT sequencing. Rapid barcoding therefore represents a cost-effective and efficient approach for routine poliovirus surveillance, whereas native barcoding remains advantageous in applications requiring rapid data generation or maximal sequencing depth.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.