MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcjo.2013.08.013

Медицинская библиотека · Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2014

Elevated white blood cell count may predict risk of orbital implant exposure.

Bee Youn-Shen, Lin Muh-Chiou, Sheu Shwu-Jiuan, Ng John D

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the risk factors for primary implant exposure after enucleation and evisceration in infected eyes.

DESIGN

Retrospective, comparative case series.

PARTICIPANTS

Patients who underwent enucleation or evisceration for infected eyes.

METHODS

Records of patients who underwent enucleation or evisceration for infected eyes with placement of solid sphere implants were reviewed. Preoperative white blood cell (WBC) count, microbiologic laboratory results, clinical features, medical treatment, and surgical methods were recorded to evaluate the risk for implant exposure.

RESULTS

Eighty-five infected eyes were collected. The mean age was 70.1 years. The positive culture rate was 69.4%. In 42 patients with endophthalmitis or panophthalmitis, the most common microorganisms were Pseudomonas aeruginosa in 6 cases (20.7%) and Klebsiella pneumoniae in 7 cases (24.1%). In 50 patients with keratitis or scleritis, the most common microorganisms were P. aeruginosa in 14 eyes (46.7%) and Fusarium in 4 eyes (13.3%). There was a 12.9% exposure rate for the 85 patients. Preoperative WBC count was significantly higher in patients with implant exposure compared with those without exposure (p = 0.04). Preoperative WBC count more than 9500 cells/L had significantly higher exposure (p = 0.001).

CONCLUSIONS

Preoperative elevated WBC count was associated with higher risk for implant exposure. Primary implantation after enucleation or evisceration may be less safe in infected eyes with high preoperative WBC count.

Для цитирования: Bee Youn-Shen, Lin Muh-Chiou, Sheu Shwu-Jiuan, Ng John D. Elevated white blood cell count may predict risk of orbital implant exposure.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2014. DOI: 10.1016/j.jcjo.2013.08.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.