Peri-operative myocardial performance in infants with Down syndrome undergoing CHD repair.
Аннотация
BACKGROUND
We aimed to characterise the impact of Down syndrome on myocardial performance and loading conditions in infants with Down syndrome and CHD over the peri-operative period by comparing them with infants matched for cardiac lesion with a normal microarray.
METHODS
Left ventricular global longitudinal strain, right ventricular free wall longitudinal strain, left ventricular end-systolic wall stress, and right ventricular systolic pressure were measured in the two groups over the peri-operative period.
RESULTS
Fifty-five infants had a diagnosis of Down syndrome and these were compared with 29 control infants. Left ventricular global longitudinal strain decreased in both groups post-operatively with the Down syndrome group demonstrating some recovery pre-discharge (18 ± 3 versus 16 ± 3 %, p = 0.01). Right ventricular longitudinal strain significantly decreased in both groups post-operatively with the control group demonstrating better recovery by hospital discharge (14 ± 4 versus 18 ± 6 %, p < 0.01). End-systolic wall stress was lower and right ventricular systolic pressure was higher in the Down syndrome group throughout the study period (all p < 0.05). Down syndrome was an independent predictor of the duration of ventilation, post-operative use of inotropes, and intensive care stay. Right ventricular longitudinal strain was an independent predictor of duration of intensive care stay.
CONCLUSION
This study demonstrates the difference between the two groups in relation to left and right ventricular function, particularly prior to discharge, and outlines the additional impact a diagnosis of Down syndrome has on myocardial performance during the peri-operative period.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.