MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.prosdent.2014.12.014

Медицинская библиотека · The Journal of prosthetic dentistry · 2015

Effect of ferrule location on the fracture resistance of crowned mandibular premolars: An in vitro study.

Samran Abdulaziz, Al-Afandi Mahmoud, Kadour Jad-Alkareem, Kern Matthias

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: How the location of a ferrule affects the fracture resistance of endodontically treated mandibular premolars is unclear.

PURPOSE: The purpose of this in vitro study was to compare the effect of ferrule location on the fracture resistance of endodontically treated mandibular premolars.

MATERIAL AND

METHODS

Seventy-two extracted human mandibular premolars were selected and divided into 6 test groups (n = 12) according to ferrule location: control group, GHT; endodontically treated teeth without endodontic posts and crowns, GCF; teeth with a 2 mm circumferential ferrule, GBF; teeth with a 2 mm buccal ferrule; GLF, teeth with a 2 mm lingual ferrule; GBLF, teeth with a 2 mm buccal and lingual ferrule; and teeth without ferrule, GWF. After glass fiber posts were cemented with a self-adhesive resin cement and foundation restorations were placed, NiCr crowns were luted to each prepared tooth. All specimens were quasistatically loaded at 30 degrees in a universal testing machine until fractured. Data were then analyzed with 1-way ANOVA, followed by multiple comparisons using the Tukey honestly significant difference test (α=.05).

RESULTS

Mean ± SD failure loads for groups ranged from 791.1 ± 177.5 N to 1086.1 ± 181.1 N. One-way ANOVA revealed a statistically significant difference between the groups (P ≤ .05). However, no statistically significant differences were observed among groups (P > .05), except between GHT (control group) and groups GBLF and GWF (P = .025, P = .022).

CONCLUSIONS

Within the limitations of this study, the location of the ferrule had no significant effect on the fracture resistance of endodontically treated mandibular premolars.

Для цитирования: Samran Abdulaziz, Al-Afandi Mahmoud, Kadour Jad-Alkareem, Kern Matthias. Effect of ferrule location on the fracture resistance of crowned mandibular premolars: An in vitro study.. The Journal of prosthetic dentistry. 2015. DOI: 10.1016/j.prosdent.2014.12.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.