MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pds.3956

Медицинская библиотека · Pharmacoepidemiology and drug safety · 2016

Instrumental variable analysis as a complementary analysis in studies of adverse effects: venous thromboembolism and second-generation versus third-generation oral contraceptives.

Boef Anna G C, Souverein Patrick C, Vandenbroucke Jan P, van Hylckama Vlieg Astrid, de Boer Anthonius, le Cessie Saskia, Dekkers Olaf M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: A potentially useful role for instrumental variable (IV) analysis may be as a complementary analysis to assess the presence of confounding when studying adverse drug effects. There has been discussion on whether the observed increased risk of venous thromboembolism (VTE) for third-generation oral contraceptives versus second-generation oral contraceptives could be (partially) attributed to confounding. We investigated how prescribing preference IV estimates compare with conventional estimates.

METHODS

Women in the Clinical Practice Research Database who started a second-generation or third-generation oral contraceptive from 1989 to 2013 were included. Ordinary least squares and two-stage least squares regression were used to estimate risk differences in VTE. Cox regression and IV for Cox proportional hazards regression were used to calculate hazard ratios (HR). The instrument used was the proportion of prescriptions for third-generation oral contraceptives by the general practitioner in the year preceding the current prescription.

RESULTS

All analyses pointed in the direction of an increased VTE risk for third-generation oral contraceptives. The adjusted HR from the conventional Cox regression was 1.62 (95% confidence interval 1.16-2.27) and the fully adjusted HR from the IV Cox regression was 3.45 (95% confidence interval; 0.97-11.7), showing a larger risk and wider confidence intervals in the IV analysis.

CONCLUSIONS

The similarity in direction of results from the IV analyses and conventional analyses suggests that major confounding is unlikely. IV analysis can be a useful complementary analysis to assess the presence of confounding in studies of adverse drug effects in very large databases.

Для цитирования: Boef Anna G C, Souverein Patrick C, Vandenbroucke Jan P, van Hylckama Vlieg Astrid, de Boer Anthonius, le Cessie Saskia, Dekkers Olaf M. Instrumental variable analysis as a complementary analysis in studies of adverse effects: venous thromboembolism and second-generation versus third-generation oral contraceptives.. Pharmacoepidemiology and drug safety. 2016. DOI: 10.1002/pds.3956.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.