MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msec.2012.12.036

Медицинская библиотека · Materials science & engineering. C, Materials for biological applications · 2012

Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo.

Zhang Zhi xiong, Fu Bu fang, Zhang De yuan, Zhang Zhi wei, Cheng Yan, Sheng Li yuan, Lai Chen, Xi Ting fei

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Atrial septal defect (ASD) occlusion devices made of nickel-titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium-nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years.

Для цитирования: Zhang Zhi xiong, Fu Bu fang, Zhang De yuan, Zhang Zhi wei, Cheng Yan, Sheng Li yuan, Lai Chen, Xi Ting fei. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo.. Materials science & engineering. C, Materials for biological applications. 2012. DOI: 10.1016/j.msec.2012.12.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.