MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vec.13107

Медицинская библиотека · Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001) · 2021

Evaluation of coccygeal and radial artery Doppler blood pressure measurements in sick cats with and without abnormalities in tissue perfusion.

De Rosa Sage M, Drobatz Kenneth J, Reineke Erica L

СтатьяObservational Study, VeterinaryПеревод в очереди

Аннотация

OBJECTIVE

To compare systolic blood pressure measured by Doppler (SBP) taken from the coccygeal artery versus common digital branch of the radial artery in cats with normal and poor perfusion parameters.

DESIGN

Prospective, observational study.

SETTING

University Teaching Hospital.

ANIMALS: Eighty-five cats presenting to the emergency service for which prior emergency treatment was not received and a blood pressure was indicated on triage.

INTERVENTIONS: Systolic blood pressure was measured by Doppler using the radial and coccygeal arteries. Cats were categorized as having normal or poor tissue perfusion based on physical examination.

MEASUREMENTS AND MAIN

RESULTS

Agreement was poor between coccygeal and radial SBP overall with absolute and relative bias (95% limits of agreement) of 23 (-51 to 96) mm Hg and 16% (-38% to 69%), respectively. In cats with poor perfusion, the agreement was absolute bias = 28 mm Hg and relative bias = 22% and with normal perfusion absolute bias = 22 mm Hg, and relative bias = 12%. The median (interquartile range) coccygeal SBP was significantly different from the radial SBP 141 (50) mm Hg versus 120 (45) mm Hg, P < 0.001. In multivariate linear regression, heart rate was negatively associated with coccygeal SBP (r2  = 0.088, P = 0.049), and pale mucous membrane color (P = 0.034) and poor pulse quality (P = 0.007) were independently associated with lower radial SBP (r2  = 0.18).

CONCLUSIONS

Median coccygeal SBP is significantly greater than radial SBP in sick cats with both normal perfusion and hypoperfusion. Agreement between coccygeal and radial SBP is poor in cats and cannot be used interchangeably. As clinically significant differences exist between sites, the authors recommend obtaining SBP from both sites initially and choosing to monitor and trend changes with the one site that correlates most with physical examination findings.

Для цитирования: De Rosa Sage M, Drobatz Kenneth J, Reineke Erica L. Evaluation of coccygeal and radial artery Doppler blood pressure measurements in sick cats with and without abnormalities in tissue perfusion.. Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). 2021. DOI: 10.1111/vec.13107.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.