Endovascular Pressure Measurements to Assess the Functional Severity of Mesenteric Arterial Stenoses.

van Dijk Louisa J D, Terlouw Luke G, van Noord Desirée, Bijdevaate Diederik C, Bruno Marco J, Moelker Adriaan

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To assess the ability of pressure measurements to discriminate clinically significant celiac artery (CA) or superior mesenteric artery (SMA) stenosis in patients with suspected chronic mesenteric ischemia (CMI).

MATERIALS AND

METHODS

Single-center, retrospective cohort study of 41 intra-arterial pressure measurements during mesenteric angiography with intended revascularization, performed in 37 patients (mean age 67.7 ± 10.8 years, 62% female) between April 2015 and May 2017. Simultaneous prestenotic and poststenotic pressure measurements had been obtained before and after intra-arterial administration of nitroglycerin. Revascularization was performed in 38 of 41 procedures. Definitive diagnosis of CMI was defined as patient-reported symptom relief or improvement after successful revascularization.

RESULTS

Pressure gradients obtained after vasodilator administration were significantly higher in CAs and SMAs with ≥50% stenosis. Pressure ratios (pressure distal [Pd]/pressure aorta [Pa]) obtained after vasodilator administration were significantly higher in CAs with ≥50% stenosis. Subgroup analysis of 22 patients with a ≥50% stenosis of either CA or SMA showed significantly higher pressure gradients and Pd/Pa ratios after vasodilator administration in CMI patients (median pressure gradient: CMI [interquartile ratio] 36 [21-40] mm Hg versus no-CMI 20 [9-21] mm Hg, P = 0.041; Pd/Pa: CMI 0.703 [0.598-0.769] versus no-CMI 0.827 [0.818-0.906], P = .009). A ≤0.8 Pd/Pa cutoff value after administration of a vasodilator best identified a clinically relevant stenosis, with 86% sensitivity and 83% specificity. Complications related to the pressure measurements were not observed.

CONCLUSIONS

Intra-arterial pressure measurements are feasible and safe. Low Pd/Pa ratios were associated with clinically relevant CA or SMA stenosis.

Для цитирования: van Dijk Louisa J D, Terlouw Luke G, van Noord Desirée, Bijdevaate Diederik C, Bruno Marco J, Moelker Adriaan. Endovascular Pressure Measurements to Assess the Functional Severity of Mesenteric Arterial Stenoses.. Journal of vascular and interventional radiology : JVIR. 2020. DOI: 10.1016/j.jvir.2019.10.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.