MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jir.13002

Медицинская библиотека · Journal of intellectual disability research : JIDR · 2022

Calibration of hip accelerometers for measuring physical activity and sedentary behaviours in adults with Down syndrome.

Agiovlasitis S, Ballenger B K, Schultz E E, Du Q, Motl R W

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

The knowledge base on physical activity and sedentary behaviour in adults with Down syndrome (DS) may advance by accelerometer calibration studies. This study aimed to develop cut-points for sedentary behaviour and moderate-to-vigorous physical activity (MVPA) for adults with DS based on output from accelerometers worn on the dominant and non-dominant hips.

METHODS

Sixteen adults with DS (10 men; age 31 ± 15 years) performed 12 tasks including sedentary behaviours and physical activities. We obtained metabolic equivalents (METs) with indirect calorimetry and vector magnitude (VM) output from triaxial accelerometers (wGT3X-BT, ActiGraph) worn on the dominant and non-dominant hips. Receiver operating characteristic curves were used to identify optimal VM cut-points that maximised sensitivity and specificity.

RESULTS

Overall classification accuracy was very high (area under the ROC curve: 0.95 and 0.92 for sedentary and MVPA models, respectively). For the non-dominant hip, the optimal VM cut-points were (1) sedentary behaviour ≤236 counts·min-1 and (2) MVPA ≥2167 counts·min-1 . For the dominant hip, optimal cut-points were (1) sedentary behaviour ≤243 counts·min-1 and (2) MVPA ≥2092 counts·min-1 .

CONCLUSIONS

The presented VM cut-points for sedentary behaviour and MVPA for adults with DS had high classification accuracy. There were small differences in accelerometer cut-points between the dominant and non-dominant hip.

Для цитирования: Agiovlasitis S, Ballenger B K, Schultz E E, Du Q, Motl R W. Calibration of hip accelerometers for measuring physical activity and sedentary behaviours in adults with Down syndrome.. Journal of intellectual disability research : JIDR. 2022. DOI: 10.1111/jir.13002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.