Indian journal of gastroenterology : official journal of the Indian Society of Gastroenterology · 2004
Accuracy and reliability of palpation and percussion for detecting hepatomegaly: a rural hospital-based study.
Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Joshi Rajnish, Singh Amandeep, Jajoo Namita, Pai Madhukar, Kalantri S P
Аннотация
BACKGROUND: Palpation and percussion are standard bedside techniques used to diagnose hepatomegaly. Ultrasonography is a noninvasive and accurate method for measurement of liver size, but many patients in developing countries have limited access to it. We compared the accuracy of palpation and percussion in a rural population in central India, using ultrasonography as a reference standard.
METHODS: The study design was a blinded, cross-sectional analysis of a hospital-based case series. Three physicians, blind to clinical data and to each other's results, independently used palpation and percussion to detect hepatomegaly. Diagnostic accuracy was measured by computing sensitivity, specificity, and likelihood ratio values. Inter-physician agreement was assessed using the kappa statistic.
RESULTS: Of the 180 study patients, 36 (20%) had enlarged liver on ultrasonography. The likelihood ratios for findings at both palpation (2.2, 3.0, and 2.5 for the three physicians, respectively) and percussion (1.1 for all three physicians) as predictors of true hepatomegaly were low. The kappa values for inter-observer agreement between three physicians for the presence of hepatomegaly at palpation (=0.44-0.53) and percussion (=0.17-0.33) were low, indicating poor reliability of these techniques.
CONCLUSION: Clinical assessment of hepatomegaly by palpation and percussion lacks both accuracy and reliability.
METHODS: The study design was a blinded, cross-sectional analysis of a hospital-based case series. Three physicians, blind to clinical data and to each other's results, independently used palpation and percussion to detect hepatomegaly. Diagnostic accuracy was measured by computing sensitivity, specificity, and likelihood ratio values. Inter-physician agreement was assessed using the kappa statistic.
RESULTS: Of the 180 study patients, 36 (20%) had enlarged liver on ultrasonography. The likelihood ratios for findings at both palpation (2.2, 3.0, and 2.5 for the three physicians, respectively) and percussion (1.1 for all three physicians) as predictors of true hepatomegaly were low. The kappa values for inter-observer agreement between three physicians for the presence of hepatomegaly at palpation (=0.44-0.53) and percussion (=0.17-0.33) were low, indicating poor reliability of these techniques.
CONCLUSION: Clinical assessment of hepatomegaly by palpation and percussion lacks both accuracy and reliability.
Предметные рубрики MeSH
AdultAgedClinical CompetenceConfidence IntervalsCross-Sectional StudiesDouble-Blind MethodFemaleHepatomegalyHospitals, RuralHumansIndiaMaleMiddle AgedOdds RatioPalpationPercussionPhysical ExaminationPredictive Value of TestsReference ValuesReproducibility of ResultsSensitivity and SpecificitySeverity of Illness IndexUltrasonography, Doppler