MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.hyp.24.6.786

Медицинская библиотека · Hypertension (Dallas, Tex. : 1979) · 1994

Systematic difference between blood pressure readings caused by cuff type.

Bovet P, Hungerbuhler P, Quilindo J, Grettve M L, Waeber B, Burnand B

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this study we determine whether blood pressure readings using a cuff of fixed size systematically differed from readings made with a triple-bladder cuff (Tricuff) that automatically adjusts bladder width to arm circumference and assessed subsequent clinical and epidemiological effects. Blood pressure was measured with a standard cuff or a Tricuff in 454 patients visiting an outpatient clinic in the Seychelles (Indian Ocean). Overall means of within-individual standard cuff-Tricuff differences in systolic and diastolic blood pressures were examined in relation to arm circumference and sex. The standard cuff-Tricuff difference in systolic and diastolic blood pressures increased monotonically with circumference (from 4.7 +/- 0.8/3.2 +/- 0.7 mm Hg for arm circumference of 30 to 31 cm to 10.0 +/- 1.1/8.0 +/- 0.9 mm Hg for arm circumference > or = 36 cm) and was larger in women than men. Multivariate linear regression indicated independent effects of arm circumference and sex. Forty percent of subjects with a diastolic blood pressure of > or = 95 mm Hg measured with a standard cuff had values less than 95 mm Hg measured with a Tricuff. Extrapolation to the entire population of the Seychelles decreased the prevalence of blood pressure greater than or equal to 160/95 mm Hg by 11.5% and 24.0% in men and women, respectively, aged 35 to 64 years. The age-adjusted effect of body mass index on systolic and diastolic blood pressures decreased twofold using blood pressure readings made with a Tricuff instead of a standard cuff.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Bovet P, Hungerbuhler P, Quilindo J, Grettve M L, Waeber B, Burnand B. Systematic difference between blood pressure readings caused by cuff type.. Hypertension (Dallas, Tex. : 1979). 1994. DOI: 10.1161/01.hyp.24.6.786.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.