BACKGROUND

Despite their improved safety, by and large, cardiac electrophysiology procedures including catheter ablation (CA), are presently performed in hospital outpatient departments.

OBJECTIVE

This large multicenter study investigated the safety and outcomes associated with various cardiac electrophysiology procedures performed at 6 ambulatory surgery centers (ASCs), primarily during the coronavirus disease 2019 pandemic under the Center for Medicare and Medicaid Services Hospitals Without Walls program.

METHODS

We retrospectively analyzed the outcomes from consecutive electrophysiology procedures performed in ASCs with same-day discharge, including transesophageal echocardiography, cardioversion, cardiac implantable electronic device (CIED) implantation, electrophysiology studies, and CA for atrial fibrillation (AF), atrial flutter (AFL)/supraventricular tachycardia, ventricular premature complexes (VPCs), and atrioventricular node.

RESULTS

Altogether, 4037 procedures were performed, including 779 transesophageal echocardiography/cardioversion procedures (19.3%), 1453 CIED implantation procedures (36.0%), 26 electrophysiology studies (0.6%), and 1779 CA procedures (44.1%) for AF (75.4%), AFL/supraventricular tachycardia (18.8%), VPC (4.7%), and atrioventricular node (1.1%). Overall, 80.2% of CA procedures were for left-sided atrial arrhythmias (AF/atypical AFL) requiring transseptal catheterization. Left-sided VPC ablation procedures (42.2%) were performed using a transseptal/retrograde approach. Adverse event rates were low, but comparable between CIED implantation and CA (0.76% vs 0.73%; P = .93), as were the incidences of urgent/unplanned postprocedure hospitalization (0.48% vs 0.45%; P = .89), respectively. Moreover, the adverse event rates in ASCs vs hospital outpatient departments did not differ for CIED (0.76% vs 0.65%; P = .71) or CA (0.73% vs 0.80%; P = .79).

CONCLUSION

The results from this large multicenter study suggest that ASCs represent a safe and effective setting to perform a variety of cardiac electrophysiology procedures including CA. These findings bear important implications for healthcare delivery and policy.

Для цитирования: Aryana Arash, Thihalolipavan Sudarone, Willcox Mark E, Swarup Somya, Zagrodzky Jason, Wang H James, Lupercio Florentino A, Kenigsberg David N, Kenigsberg Sophia, Mahapatra Rhea A, O'Neill Padraig Gearoid, Compton Steven J, Natale Andrea, Ellenbogen Kenneth A, Swarup Vijendra. Safety and feasibility of cardiac electrophysiology procedures in ambulatory surgery centers.. Heart rhythm. 2024. DOI: 10.1016/j.hrthm.2024.07.123.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.