The International journal of artificial organs · 2025

Development and validation of machine learning predictive models for assessing dialysis adequacy in dialysis patients.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhou Jie, Wu Hao, Zhang Linge, Zhang Qiaona, Wang Jie, Zhao Hang, Dang Yongqi, Zhang Shiyu, Li Lu

Аннотация

PURPOSE: The assessment of dialysis adequacy is of great clinical importance. However, it depends on the nonlinear effects of numerous confounding factors and is therefore difficult to predict using traditional statistical methods. In this study, we used Random Forest (RF), Extreme Gradient Boosting (XGBoost), and Least Absolute Shrinkage and Selection Operator Regression (LASSO) to assess dialysis adequacy.

METHODS: A training set (70%) and a test set (30%) were randomly selected from the 264 dialysis patient case records collected for this study. We compared the machine learning models with statistical logistic regression prediction models. In addition, we performed fivefold cross internal validation and external validation.

RESULTS: The test dataset showed sensitivity values of 0.86 (95% CI = 0.75-0.96), 0.81 (95% CI = 0.69-0.93), and 0.72 (95% CI = 0.58-0.85) for the RF, XGBoost, and LASSO models, respectively. The matched specificity was 0.73 (95% CI = 0.58-0.87), 0.81 (95% CI = 0.67-0.93), and 0.83 (95% CI = 0.71-0.95). Accuracy was 0.80 (95% CI = 0.71-0.89), 0.81 (95% CI = 0.72-0.90), and 0.77 (95% CI = 0.68-0.86). F1 scores were 0.83 (95% CI = 0.72-0.90), 0.82 (95% CI = 0.73-0.91), and 0.78 (95% CI = 0.67-0.87). The receiver operating characteristic curves (AUROC) were 0.88 (p < 0.05, 95% CI = 0.70-0.88), 0.86 (p = 0.12, 95% CI = 0.72-0.90), and 0.88 (p < 0.05, 95% CI = 0.69-0.86). The mean absolute errors (MAE) of the calibration curves were 0.15, 0.11, and 0.07. In addition, the decision curve analysis (DCA) showed wide intervals of net clinical benefit for the models.

CONCLUSION: Machine learning can be used to predict dialysis adequacy for optimal RF performance.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты