Effectiveness of amiodarone versus digitalis for heart rate control in critically ill patients with new-onset atrial fibrillation.

Gillmann Hans-Joerg, Busche Philipp, Leffler Andreas, Stueber Thomas

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

New-onset of atrial fibrillation (NOAF) in critically ill patients is the most common acute cardiac dysrhythmia, but evidence-based data regarding treatment strategies are scarce. In this retrospective monocentric study, we compared effectiveness of amiodarone versus digitalis for heart rate control in critically ill patients with new-onset of atrial fibrillation. We identified a total of 209 patients for the main analysis. Amiodarone as compared to digitalis was associated with a clinically relevant faster time to heart rate control < 110 bpm (2 h (IQR: 1 h to 6 h) versus 4 h (2 h to 12 h); p = 0.003) and longer durations of sinus rhythm during the first 24 h of treatment (6 h (IQR: 6 h to 22 h) versus 0 h (IQR: 0 h to 16 h); p < 0.001). However, more bradycardic episodes occurred in association with amiodarone than with digitalis (7.7% versus 3.4%; p = 0.019). Use of amiodarone was associated with an increase of noradrenalin infusion rate compared to digitalis (23.9% versus 12.0%; p = 0.019). Within the tertile of patients with the highest CRP measurements, amiodarone treated patients presented with a higher decrease in heart rate than digoxin treated patients. Clinical trials comparing different NOAF treatment strategies are much needed and should report on concomitant sympathetic activity and inflammatory status.

Для цитирования: Gillmann Hans-Joerg, Busche Philipp, Leffler Andreas, Stueber Thomas. Effectiveness of amiodarone versus digitalis for heart rate control in critically ill patients with new-onset atrial fibrillation.. Scientific reports. 2022. DOI: 10.1038/s41598-022-06639-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.