MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejechocard/jen003

Медицинская библиотека · European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology · 2008

Early impairment of left ventricular long-axis systolic function demonstrated by reduced atrioventricular plane displacement in patients with Marfan syndrome.

Kiotsekoglou Anatoli, Bajpai Abhay, Bijnens Bart H, Kapetanakis Venedictos, Athanassopoulos George, Moggridge James C, Mullen Mike J, Nassiri Dariush K, Camm John, Sutherland George R, Child Anne H

СтатьяМетаанализПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: Marfan syndrome (MFS) is a connective tissue disorder caused by mutations in the fibrillin-1 (FBN1) gene. It has been observed that FBN1 deficient mice have reduced left ventricular (LV) systolic function which is correlated to increased transforming growth factor-beta activity. This study aimed to ascertain LV functional abnormalities in MFS patients using M-mode and tissue Doppler imaging (TDI).

METHODS AND

RESULTS

In 66 (15-58 years) MFS patients and 61 normal controls, ejection fraction (EF) was evaluated by Simpson's biplane method. Atrioventricular plane displacement (AVPD) obtained from five mitral annular regions was also assessed using M-mode and TDI techniques. To overcome limitations associated with conventional M-mode echocardiography, anatomical and colour anatomical M-mode were also utilized. Ejection fraction was significantly reduced in MFS patients when compared to controls (66.3 +/- 0.74 vs. 71.9 +/- 0.56, P < 0.001), although it was within the normal range. M-mode and TDI AVPD measurements obtained from lateral, septal, inferior, anterior and posterior mitral annular regions were also significantly reduced in MFS patients in comparison to controls (P <0.001, for all measurements).

CONCLUSION

Left ventricular long-axis systolic function is significantly reduced in MFS patients. This data suggests that LV function should be monitored in MFS and appropriate treatment applied if necessary.

Для цитирования: Kiotsekoglou Anatoli, Bajpai Abhay, Bijnens Bart H, Kapetanakis Venedictos, Athanassopoulos George, Moggridge James C, Mullen Mike J, Nassiri Dariush K, Camm John, Sutherland George R, Child Anne H. Early impairment of left ventricular long-axis systolic function demonstrated by reduced atrioventricular plane displacement in patients with Marfan syndrome.. European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology. 2008. DOI: 10.1093/ejechocard/jen003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.