Differences in breathing patterning during wakefulness in patients with mixed apnea-dominant vs obstructive-dominant sleep apnea.

Yamauchi Motoo, Tamaki Shinji, Yoshikawa Masanori, Ohnishi Yoshinobu, Nakano Hiroshi, Jacono Frank J, Loparo Kenneth A, Strohl Kingman P, Kimura Hiroshi

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Mixed apneas share both central and obstructive components and are often treated as if they are obstructive events. The hypothesis is that patients with obstructive sleep apnea syndrome (OSAS) who exhibit a majority of mixed apneas will differ in ventilatory control from those with predominantly obstructive apneas during wakefulness; moreover, this difference could affect nasal continuous positive airway pressure (CPAP) adherence.

METHODS

In a retrospectively derived case-control study, 5 min of respiratory inductance plethysmography signals during wakefulness prior to sleep onset were extracted from a diagnostic polysomnogram in these groups: (1) mixed apnea-dominant OSAS (mix-OSAS) (n = 36), (2) obstructive apnea-dominant OSAS (pure-OSAS) (n = 20), (3) central apnea-dominant sleep apnea syndrome (pure-CSAS) (n = 6), and (4) control subjects (n = 10). Breathing patterning was compared between the groups using the coefficient of variation (CV) for breath-to-breath inspiration time (TI), expiration time (TE), TI + TE (Ttot), and tidal volume, and an information theory-based metric of signal pattern variability (sample entropy). Subsequent CPAP adherence over 12 months was determined in OSAS groups.

RESULTS

Breath-to-breath CV parameters and sample entropy in the mix-OSAS group were significantly greater as compared with the pure-OSAS and control groups. In a subanalysis, CV and sample entropy were similar in the mix-OSAS and the pure-CSAS groups. CPAP adherence was significantly poorer in mix-OSAS compared with pure-OSAS.

CONCLUSIONS

During wakefulness, both breath patterning and sample entropy in mix-OSAS are similar to pure-CSAS and more variable than in pure-OSAS. In addition, CPAP adherence was decreased in patients with mix-OSAS, which may be related to basic differences in respiratory control.

Для цитирования: Yamauchi Motoo, Tamaki Shinji, Yoshikawa Masanori, Ohnishi Yoshinobu, Nakano Hiroshi, Jacono Frank J, Loparo Kenneth A, Strohl Kingman P, Kimura Hiroshi. Differences in breathing patterning during wakefulness in patients with mixed apnea-dominant vs obstructive-dominant sleep apnea.. Chest. 2011. DOI: 10.1378/chest.10-1082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.