DOI 10.1053/j.ajkd.2006.01.033

Медицинская библиотека · American journal of kidney diseases : the official journal of the National Kidney Foundation · 2006

Forearm venous distensibility predicts successful arteriovenous fistula.

van der Linden Joke, Lameris Thomas W, van den Meiracker Anton H, de Smet André A E A, Blankestijn Peter J, van den Dorpel Marinus A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The success of a newly created arteriovenous fistula (AVF) depends on sufficient maturation of the forearm vein used. This maturation fails in up to 50%. We hypothesize that impairment of forearm venous distensibility, ie, the ability of veins to adjust to increased pressure, is related to AVF failure.

METHODS

Forearm venous distensibility was measured by using strain-gauge plethysmography in 27 patients with end-stage renal failure awaiting vascular access surgery; either AVF or graft (AVG) formation. Ultrasound duplex scanning of the upper-extremity circulation was performed 4 weeks before surgery. Failure to mature is defined as inability to use the AVF for hemodialysis within 8 weeks after surgery.

RESULTS

Venous distensibility in patients receiving an AVG (n = 10) was 0.44 +/- 0.05 mL/mm Hg, and in patients receiving an AVF (n =17), 0.56 +/- 0.04 mL/mm Hg (P = 0.2). Venous distensibility was 0.46 +/- 0.03 mL/mm Hg in patients with an unsuccessful AVF (n = 9) and 0.66 +/- 0.05 mL/mm Hg in patients with a successful AVF (n = 8; P = 0.003). All 7 patients with venous distensibility of 0.50 mL/mm Hg or less had a nonfunctional AVF (100%), whereas only 2 of 10 patients with venous distensibility greater than 0.50 mL/mm Hg had a nonfunctional AVF (20%; P = 0.002). No differences were found in arterial and venous luminal diameters between functional and nonfunctional AVFs.

CONCLUSION

These preliminary results suggest that forearm venous distensibility is a predictor of AVF success, whereas luminal diameters are not. Measurement of venous distensibility may be helpful in choosing the most suitable access type for each individual patient, possibly improving access patency.

Для цитирования: van der Linden Joke, Lameris Thomas W, van den Meiracker Anton H, de Smet André A E A, Blankestijn Peter J, van den Dorpel Marinus A. Forearm venous distensibility predicts successful arteriovenous fistula.. American journal of kidney diseases : the official journal of the National Kidney Foundation. 2006. DOI: 10.1053/j.ajkd.2006.01.033.