MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-022-02906-9

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022

Image-derived and physiological markers to predict adequate adenosine-induced hyperemic response in Rubidium-82 myocardial perfusion imaging.

Lassen Martin Lyngby, Wissenberg Mads, Byrne Christina, Sheykhzade Majid, Hurry Preetee Kapisha, Schmedes Anne Vibeke, Kjær Andreas, Hasbak Philip

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: This study aimed to investigate the potential of different markers to identify adequate stressing in subjects with and without caffeine intake prior to Rubidium-82 myocardial imaging.

METHODS AND

RESULTS

This study comprised 40 healthy subjects who underwent four serial Rubidium-82 rest/adenosine stress MPI; two with 0mg caffeine consumption (baseline MPIs) and two with controlled consumption of caffeine (arm 1: 100 and 300mg, or arm 2: 200 and 400mg). We report the sensitivity and specificity of seven markers ability to predict adequate adenosine-induced hyperemic response: (1) the splenic response ratio (SRR); (2) splenic stress-to-rest intensity ratios (SIR); (3) changes in heart rate (ΔHR); (4) percentwise change in heart rate (Δ%HR); (5) changes in the rate pressure product (ΔRPP); (6) changes in the systolic blood pressure (ΔSBP); and (7) changes in the cardiovascular resistance (ΔCVR). Adequate stressing was determined as stress myocardial blood flow > 3ml/g/min and a corresponding myocardial flow reserve >68% of the individual maximum myocardial flow reserve obtained in the baseline MPIs.

RESULTS

129 MPI sessions (obtained in 39 subjects) were considered for this study. The following sensitivities were obtained: SSR = 72.7%, SIR = 63.6%, ΔHR = 45.5%, Δ%HR = 77.3%, ΔRPP = 54.5%, ΔSBP = 47.7%, and ΔCVR =40.9%, while the specificities were SSR = 80.9%, SIR = 85.0%, ΔHR = 90.4%, Δ%HR = 81.6%, ΔRPP=81.1%, ΔSBP = 86.4%, and ΔCVR =90.4%.

CONCLUSION

The image-derived and physiological markers all provide acceptable sensitivities and specificities when patients follow the caffeine pausation before MPI. However, their use warrants great care when caffeine consumption cannot be ruled out.

Для цитирования: Lassen Martin Lyngby, Wissenberg Mads, Byrne Christina, Sheykhzade Majid, Hurry Preetee Kapisha, Schmedes Anne Vibeke, Kjær Andreas, Hasbak Philip. Image-derived and physiological markers to predict adequate adenosine-induced hyperemic response in Rubidium-82 myocardial perfusion imaging.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2022. DOI: 10.1007/s12350-022-02906-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.