MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.174.5.1741257

Медицинская библиотека · AJR. American journal of roentgenology · 2000

Accuracy of screening mammography using single versus independent double interpretation.

Taplin S H, Rutter C M, Elmore J G, Seger D, White D, Brenner R J

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

OBJECTIVE

We conducted an analysis among 31 community radiologists to identify the average change in screening mammography interpretive accuracy afforded by independent double interpretation.

MATERIALS AND

METHODS

We assessed interpretive accuracy using a stratified random sample of test mammograms that included 30 women with cancer and 83 without. Radiologists were unaware of clinical information and of each other's assessments. We describe accuracy for individual radiologists and for double interpretation, including average sensitivity, specificity, diagnostic likelihood ratios positive and negative, and area under the receiver operating characteristic (ROC) curve. We also assessed weighted and nonweighted kappa statistics among all 465 pairs of radiologists and 31,465 pairs of unique pairs. The assessment for double interpretations used the "highest" (i.e., most abnormal) assessment of the two radiologists. We calculated the difference between each radiologist's individual accuracy and the average accuracy across that radiologist's 30 double interpretations.

RESULTS

We found the following average accuracy statistics for individual radiologists: sensitivity, 79%; specificity, 81%; diagnostic likelihood ratio positive, 5.53; diagnostic likelihood ratio negative, 0.26; and area under the ROC curve, 0.85. The mean kappa statistic among radiologists for cancer cases increased with double interpretation from 0.59 to 0.70, and for noncancer cases from 0.30 to 0.34. Double interpretation resulted in an average increase in sensitivity of 7%, an average decrease in specificity of 11%, a decrease in diagnostic likelihood ratio positive of 2.35, a decrease in diagnostic likelihood ratio negative of 0.06, and an increase in area under the ROC curve of 0.02.

CONCLUSION

Independent double interpretation does not increase accuracy as measured by the area under the ROC curve.

Для цитирования: Taplin S H, Rutter C M, Elmore J G, Seger D, White D, Brenner R J. Accuracy of screening mammography using single versus independent double interpretation.. AJR. American journal of roentgenology. 2000. DOI: 10.2214/ajr.174.5.1741257.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.