BACKGROUND

Minimally invasive cardiac surgery has emerged as an alternative to conventional open surgery. This report reviews our experience with atrial septal defect using the da VinciTM surgical robot system.

MATERIALS AND

METHODS

This retrospective study included 50 consecutive patients who underwent atrial septal defect repair using the da VinciTM surgical robot system between October 2007 and May 2011. Among these, 13 patients (26%) were approached through a totally endoscopic approach and the others by mini-thoracotomy. Nineteen patients had concomitant procedures including tricuspid annuloplasty (n=10), mitral valvuloplasty (n=9), and maze procedure (n=4). The mean follow-up duration was 16.9±10.4 months.

RESULTS

No remnant interatrial shunt was detected by intraoperative or postoperative echocardiography. The atrial septal defects were mainly repaired by Gore-Tex patch closure (80%). There was no operative mortality or serious surgical complications. The aortic cross clamping time and cardiopulmonary bypass time were 74.1±32.2 and 157.6±49.7 minutes, respectively. The postoperative hospital stay was 5.5±3.3 days.

CONCLUSION

The atrial septal defect repair with concomitant procedures like mitral valve repair or tricuspid valve repair using the da VinciTM system is a feasible method. In addition, in selected patients, complete port access can be helpful for better cosmetic results and less musculoskeletal injury.

Для цитирования: Kim Ji Eon, Jung Sung-Ho, Kim Gwan Sic, Kim Joon Bum, Choo Suk Jung, Chung Cheol Hyun, Lee Jae Won. Surgical Outcomes of Congenital Atrial Septal Defect Using da VinciTM Surgical Robot System.. The Korean journal of thoracic and cardiovascular surgery. 2013. DOI: 10.5090/kjtcs.2013.46.2.93.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.