Early detection of doxorubicin-induced cardiotoxicity in rats by its cardiac metabolic signature assessed with hyperpolarized MRI.

Timm Kerstin N, Perera Charith, Ball Vicky, Henry John A, Miller Jack J, Kerr Matthew, West James A, Sharma Eshita, Broxholme John, Logan Angela, Savic Dragana, Dodd Michael S, Griffin Julian L, Murphy Michael P, Heather Lisa C, Tyler Damian J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Doxorubicin (DOX) is a widely used chemotherapeutic agent that can cause serious cardiotoxic side effects culminating in congestive heart failure (HF). There are currently no clinical imaging techniques or biomarkers available to detect DOX-cardiotoxicity before functional decline. Mitochondrial dysfunction is thought to be a key factor driving functional decline, though real-time metabolic fluxes have never been assessed in DOX-cardiotoxicity. Hyperpolarized magnetic resonance imaging (MRI) can assess real-time metabolic fluxes in vivo. Here we show that cardiac functional decline in a clinically relevant rat-model of DOX-HF is preceded by a change in oxidative mitochondrial carbohydrate metabolism, measured by hyperpolarized MRI. The decreased metabolic fluxes were predominantly due to mitochondrial loss and additional mitochondrial dysfunction, and not, as widely assumed hitherto, to oxidative stress. Since hyperpolarized MRI has been successfully translated into clinical trials this opens up the potential to test cancer patients receiving DOX for early signs of cardiotoxicity.

Для цитирования: Timm Kerstin N, Perera Charith, Ball Vicky, Henry John A, Miller Jack J, Kerr Matthew, West James A, Sharma Eshita, Broxholme John, Logan Angela, Savic Dragana, Dodd Michael S, Griffin Julian L, Murphy Michael P, Heather Lisa C, Tyler Damian J. Early detection of doxorubicin-induced cardiotoxicity in rats by its cardiac metabolic signature assessed with hyperpolarized MRI.. Communications biology. 2020. DOI: 10.1038/s42003-020-01440-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.