[Misplacement of central venous catheters in the subclavian artery: safe retrieval with a percutaneous closure device (AngioSeal)].
Аннотация
PURPOSE: To evaluate the feasibility of retrieval of misplaced central venous catheters in the subclavian artery with a percutaneous closure device (AngioSeal).
MATERIALS AND
METHODS
According to the radiologic information system of a university hospital, 7 patients (6 women, 1 child) underwent removal of a misplaced central venous catheter (4 × 7 F, 1 × 8 F, 2 × 13 F) in the subclavian artery between January 2008 and June 2012 with the 8 F percutaneous closure device AngioSeal. The body mass index (BMI) of 7 patients was available, 3 of whom were obese (BMI 2 × 35.7 and 1 × 33.0). Both 13 F catheters were removed in a balloon-supported manner as described elsewhere. The Broviak catheter of a 21-month-old boy was removed by surgical support with preparation of the catheter to its vessel entry. Success control was done by a transfemoral DSA in 5 of the 7 patients. 2 patients received clinical follow-up.
RESULTS
In all cases the misplaced catheter could be removed successfully. In all 7 patients, there was no arterial bleeding after catheter removal. Complications were not observed.
CONCLUSION
Removal of misplaced central venous catheters in the subclavian artery by the percutaneous closure device AngioSeal is safe. Percutaneous catheter removal should be regarded as the method of choice, even in obese patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.