Diastolic flow parameters are not sensitive in predicting necrotizing enterocolitis in patients undergoing hybrid procedure.

Cozzi Corin, Stines Jack, Luce Wendy A, Hayes John, Cheatham John P, Galantowicz Mark, Cua Clifford L

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Necrotizing enterocolitis (NEC) is a significant cause of morbidity and mortality in neonates with complex single-ventricle anatomy undergoing stage I palliation. Hybrid approach is another option for initial single-ventricle palliation. The goal of this study was to determine if there were differences in echocardiographic indices between patients undergoing the hybrid procedure who developed NEC vs. those that did not develop NEC.

METHODS

Retrospective chart review was performed on patients who underwent the hybrid procedure. Patients were included if an echocardiogram with adequate Doppler tracings through the patent ductus arteriosus stent was available. Echocardiographic indices measured included antegrade velocity-time integral (VTI), retrograde VTI, effective VTI, VTI regurgitant fraction, VTI retrograde/VTI antegrade ratio, calculated cardiac output, peak antegrade velocity through the ductal stent, retrograde/antegrade time ratio, and percent regurgitant time. Indices were compared in patients who developed NEC (NEC Group) and those who did not develop NEC (No NEC Group). NEC was defined as a Bell Stage ≥2.

RESULTS

Sixty-nine patients met inclusion criteria. Eight of the 69 patients developed NEC. There was no significant difference between the NEC and No NEC Group for antegrade VTI (10.4 ± 3.2 cm vs. 12.7 ± 4.4 cm), retrograde VTI (5.3 ± 1.5 cm vs. 6.1 ± 2.2 cm), effective VTI (5.1 ± 2.9 cm vs. 6.6 ± 3.3 cm), VTI regurgitant fraction (53.6 ± 14.7% vs. 49.7 ± 13.6%), and VTI retrograde/VTI antegrade ratio (0.54 ± 0.15 vs.0.50 ± 0.14). Cardiac output (4.2 ± 1.4 L/min/m(2) vs. 4.8 ± 1.8 L/min/m(2) ) and peak velocity (117.5 ± 28.9 cm/s and 142.4 ± 42.6 cm/s) were also not different between the NEC and No NEC Groups. Furthermore, retrograde/antegrade time ratios (1.6 ± 0.2 vs. 1.7 ± 0.3) and percent retrograde time (60.6 ± 3.0% vs. 62.0 ± 4.0%) were not different between the NEC and No NEC Groups.

CONCLUSION

Echocardiographic indices were not sensitive in determining the development of NEC in patients undergoing the hybrid procedure. Larger studies with more sensitive imaging techniques are required to help risk stratify NEC in this complex patient population.

Для цитирования: Cozzi Corin, Stines Jack, Luce Wendy A, Hayes John, Cheatham John P, Galantowicz Mark, Cua Clifford L. Diastolic flow parameters are not sensitive in predicting necrotizing enterocolitis in patients undergoing hybrid procedure.. Congenital heart disease. 2012. DOI: 10.1111/chd.12017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.