DOI 10.1016/j.anai.2024.03.022
Polyethylene glycol hypersensitivity, patient outcomes in a 7-year retrospective study.
Аннотация
BACKGROUND
Immediate IgE-mediated hypersensitivity reactions to polyethylene glycol (PEG) are rare. Our understanding of PEG hypersensitivity is limited.
OBJECTIVE
To evaluate the clinical characteristics and investigation outcomes of the largest cohort of patients with PEG allergy reported.
METHODS
A total of 44 patients investigated for suspected PEG allergy across 4 United Kingdom tertiary allergy centers between October 2013 and December 2020 were studied. Clinical characteristics, index reaction, and approaches to and outcomes of allergy investigations were analyzed.
RESULTS
PEG hypersensitivity was confirmed in 42 of 44 cases. Macrogol laxatives were the most common index drugs reported (23%), followed by depo-medroxyprogesterone (19%), oral penicillin V (10%), and depo-methylprednisolone (10%). In general, 61% experienced grade III anaphylaxis. Intradermal testing (IDT) increased the diagnostic sensitivity from 51% to 85%. Five patients experienced systemic reactions during IDT. Of the 5 patients, 2 were skin prick test positive to a high molecular weight PEG. Three patients with negative skin test results had positive drug provocation test results. Seven patients with PEG allergy reported tolerance to H1-antihistamines containing PEG. Administration of messenger RNA COVID-19 or Oxford/AstraZeneca COVID-19 vaccines was tolerated in all 16 patients to whom they were administered.
CONCLUSION
PEG hypersensitivity is an uncommon cause of drug-induced anaphylaxis. Four index drugs accounted for two-thirds of the cases, and reactions to these drugs should prompt PEG hypersensitivity investigations. PEG IDT increases diagnostic yield. The role of skin prick test with higher molecular weight PEGs requires further attention. Further studies are required to understand PEG thresholds and PEG equivalent doses of various administration routes. COVID-19 vaccines were tolerated by all exposed.