DOI 10.1111/j.1440-1754.1996.tb00964.x
Effect of phototherapy on thyroid stimulatory hormone and free thyroxine levels.
Аннотация
OBJECTIVE
To study the effect of phototherapy for neonatal hyperbilirubinaemia on thyroid function as neonatal thyroid screening is sometimes performed during exposure to phototherapy.
METHODOLOGY: Infants with non-haemolytic hyperbilirubinaemia were sequentially allocated to fibre-optic phototherapy, conventional daylight phototherapy, or a combination of both. Bilirubin concentration was monitored 12 hourly by capillary blood sampling; venous blood was sampled for thyroid stimulating hormone (TSH) and free thyroxine (fT4) determinations, at start of exposure, at 24 h, end of exposure and 1 day later. Comparable unexposed infants served as controls.
RESULTS
All 123 study infants and 25 controls remained well during the study. Bilirubin levels declined during phototherapy, being most rapid in the combination group. The TSH and fT4 values at start of exposure were 3.86 +/- 0.41 mU/L (mean +/- SEM) and 33.20 +/- 1.16 pmol/L, respectively, in the fibre-optic group, 3.62 +/- 0.38 mU/L and 37.22 +/- 1.76 pmol/L in the daylight group, and 4.40 +/- 0.48 mU/L and 29.91 +/- 1.13 pmol/L in the combined group, compared with 5.77 +/- 0.40 mU/L and 34.46 +/- 1.68 pmol/L in the control group. The TSH and fT4 values declined with increasing age in the phototherapy and control groups with end of exposure values of 2.90 +/- 0.28 mU/L and 27.71 +/- 0.71 pmol/L, 2.77 +/- 0.31 mU/L and 33.52 +/- 1.22 pmol/L, and 3.44 +/- 0.30 mU/L and 27.54 +/- 0.88 pmol/L, respectively, compared with 4.21 +/- 0.61 mU/L and 27.19 +/- 2.33 pmol/L (at 72 h) in the control group. The pattern of TSH and fT4 decline in the exposed and control groups was similar, being related to increasing age.
CONCLUSIONS
The validity of neonatal thyroid screening is not affected by fibre-optic or conventional phototherapy or by both combined.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.