MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.redox.2022.102401

Медицинская библиотека · Redox biology · 2022

Stable isotope dilution mass spectrometry quantification of hydrogen sulfide and thiols in biological matrices.

Malaeb Hind, Choucair Ibrahim, Wang Zeneng, Li Xinmin S, Li Lin, Boyd W Christopher, Hine Christopher, Tang W H Wilson, Gogonea Valentin, Hazen Stanley L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Hydrogen sulfide (H2S), a gaseous signaling molecule that impacts multiple physiological processes including aging, is produced via select mammalian enzymes and enteric sulfur-reducing bacteria. H2S research is limited by the lack of an accurate internal standard-containing assay for its quantitation in biological matrices.

METHODS

After synthesizing [34S]H2S and developing sample preparation protocols that avoid sulfide contamination with the addition of thiol-containing standards or reducing reagents, we developed a stable isotope-dilution high performance liquid chromatography tandem-mass spectrometry (LC-MS/MS) method for the simultaneous quantification of Total H2S and other abundant thiols (cysteine, homocysteine, glutathione, glutamylcysteine, cysteinylglycine) in biological matrices, conducted a 20-day analytical validation/normal range study, and then both analyzed circulating Total H2S and thiols in plasma from 400 subjects, and within 20 volunteers before and after antibiotic-induced suppression of gut microbiota.

RESULTS

Using the new assay, all analytes showed minimal interference, no carryover, and excellent intra- and inter-day reproducibility (≤7.6%, and ≤12.7%, respectively), linearity (r2 > 0.997), recovery (90.9%-110%) and stability (90.0%-100.5%). Only circulating Total H2S levels showed significant age-associated reductions in both males and females (p < 0.001), and a marked reduction following gut microbiota suppression (mean 33.8 ± 17.7%, p < 0.001), with large variations in gut microbiota contribution among subjects (range 6.0-66.7% reduction with antibiotics).

CONCLUSIONS

A stable-isotope-dilution LC-MS/MS method is presented for the simultaneous quantification of Total H2S and multiple thiols in biological matrices. We then use this assay panel to show a striking age-related decline and gut microbiota contribution to circulating Total H2S levels in humans.

Для цитирования: Malaeb Hind, Choucair Ibrahim, Wang Zeneng, Li Xinmin S, Li Lin, Boyd W Christopher, Hine Christopher, Tang W H Wilson, Gogonea Valentin, Hazen Stanley L. Stable isotope dilution mass spectrometry quantification of hydrogen sulfide and thiols in biological matrices.. Redox biology. 2022. DOI: 10.1016/j.redox.2022.102401.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.