MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wasman.2017.06.049

Медицинская библиотека · Waste management (New York, N.Y.) · 2017

Highly efficient combustion with low excess air in a modern energy-from-waste (EfW) plant.

Strobel Reto, Waldner Maurice H, Gablinger Helen

СтатьяПеревод в очереди

Аннотация

The effect of low excess air and high adiabatic combustion temperatures on CO and NOx formation has been investigated on a commercially operated energy-from-waste plant. With optimal combination of low O2 levels and stable combustion control, uncontrolled NOx levels could be lowered to 100-150mg/Nm3 (dry, at 11% O2) while keeping CO emissions at low levels. Even at adiabatic temperatures above 1400°C thermal NOx hardly contributed to the total NOx emissions in a grate-fired EfW plant. An advanced combustion control system allowed continuous operation with very little excess air (λ<1.2) while keeping CO and NOx at levels well below the legal emission limits.

Для цитирования: Strobel Reto, Waldner Maurice H, Gablinger Helen. Highly efficient combustion with low excess air in a modern energy-from-waste (EfW) plant.. Waste management (New York, N.Y.). 2017. DOI: 10.1016/j.wasman.2017.06.049.