Simple, fast and eco-friendly micro-solid phase extraction based on thiol and ionic liquid bi-functional nanofibers membrane for the determination of sulfonamides in environmental water.
Аннотация
BACKGROUND
Sulfonamides (SAs) are a class of synthetic antibacterial agents that are diffusely used in the medical industry and animal husbandry. Their prevalence in the influents and effluents of water treatment plants, as well as in rivers and groundwater, has provoked worldwide concern. Monitoring SAs in environmental water is of great significance for public health. However, most of the available detection techniques for SAs are cumbersome and time-consuming. With the increasing number of actual samples, simple, fast and environmentally friendly analytical methods are always in demand.
RESULTS
Herein, we describe a highly efficient micro-solid phase extraction (μ-SPE) sample preparation technique based on a novel thiol and ionic liquid bi-functional nanofibers membrane (IL-SH-PAN NFsM) for multi-residue detection of sulfonamides (SAs) in water samples. By the synergistic effect of -SH and -IL, the as-prepared IL-SH-PAN NFsM demonstrated high adsorption capacity and excellent selectivity for SAs. The water samples can be directly used for μ-SPE without pH and ionic strength adjustment, and the eluent can be directly collected for HPLC-MS/MS analysis. Compared with other methods reported in the literature, this method required much shorter extraction time (2 min for a batch), much less amount of adsorbent (4.0 mg) and organic solvent (0.5 mL), while providing much higher sensitivity (1.4-3.9 ng L-1), and fine recoveries (88.8%-117.7%) with relative standard deviations less than 4.26%.
SIGNIFICANCE AND NOVELTY: A bi-functional nanofibers membrane was prepared for efficient extraction of SAs. The adsorbent exhibited superior adsorption performance and excellent selectivity. The underlying interaction mechanisms derived from -SH and -IL were proposed, which provide a new idea for preparing versatile adsorbents. Rapid, efficient and sensitive detection of SAs in water was achieved. The novel sample preparation technique can be expected as an efficient method for routine trace SAs residue monitoring in various water samples.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.