MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3344/kjp.2019.32.3.178

Медицинская библиотека · The Korean journal of pain · 2019

Systemic effects of fluoroscopically guided epidural steroid injection with dexamethasone.

Kang Woo Young, Lee Joon Woo, Lee Eugene, Kang Yusuhn, Ahn Joong Mo, Kang Heung Sik

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Epidural steroid injections (ESIs) have been widely used in managing spinal pain. Dexamethasone has recently emerged as a useful drug in this setting, relative to particulate steroids, although the associated systemic effects have not been fully elucidated. This study aimed to investigate the incidences and types of systemic effects after fluoroscopically guided ESI with dexamethasone.

METHODS

This retrospective study included 888 ESIs with dexamethasone (fluoroscopically guided at the cervical and lumbosacral levels) performed on 825 patients during January to June 2017. Data regarding systemic effects were collected via telephone interviews using a standardized questionnaire at 2 weeks after the procedure. Data on patient demographic, clinical, and procedural characteristics were collected and analyzed to identify factors that were associated with systemic effects. All statistical analyses were performed using the chi-squared test.

RESULTS

Among the 825 patients, 40 patients (4.8%) experienced systemic effects during the 2-week follow-up period. The most common systemic effect was facial flushing (12 patients, 1.5%), which was followed by urticaria (7 patients, 0.8%) and insomnia (7 patients, 0.8%). A history of spine surgery was significantly associated with the occurrence of systemic effects (P = 0.036). Systemic effects were significantly more common for injections at the cervical level than at the lumbar level (P = 0.019).

CONCLUSIONS

Approximately 4.8% of the patients who underwent ESI with dexamethasone experienced minor and transient systemic effects. These effects were more common in patients who had undergone a previous spine surgery or received a cervical ESI.

Для цитирования: Kang Woo Young, Lee Joon Woo, Lee Eugene, Kang Yusuhn, Ahn Joong Mo, Kang Heung Sik. Systemic effects of fluoroscopically guided epidural steroid injection with dexamethasone.. The Korean journal of pain. 2019. DOI: 10.3344/kjp.2019.32.3.178.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.