DOI 10.1097/scs.0000000000003207

Медицинская библиотека · The Journal of craniofacial surgery · 2017

Changes at Mean Platelet Volume and Platelet Distribution Width Levels After Septoplasty and Its Correlation With Epworth Sleepness Scale.

Sahin Murat S, Kizilirmak Deniz

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Nasal septum deviation may affect cardiopulmonary system. Those effects can be determined via blood tests and Epworth sleepness scale (ESS). In this study, it was aimed to measure mean platelet volume (MPV) and platelet distribution width (PDW) in patients with nasal septum deviation and to assess changes at their levels after septoplasty. Furthermore, it was purposed to document the correlation between ESS score and MPV, PDW levels.

METHODS

Eighty-one patients who underwent septoplasty and 50 healthy controls composed the study group. Epworth sleepness scale was performed to all patients preoperatively and patients were divided into 2 groups in terms of ESS scores. Mean platelet volume and PDW levels were measured preoperatively and it was repeated postoperatively.

RESULTS

In Group A (ESS <10), MPV reduced from 8.48 ± 0.38 fl to 8.47 ± 0.36 fl (P >0.05), PDW reduced from 14.56 ± 1.27% to 14.43 ± 1.03% after surgery (P >0.05). On the other hand, in Group B (ESS ≥10), MPV reduced from 9.54 ± 0.68 fl to 8.87 ± 0.44 fl (P <0.001), PDW reduced from 17.15 ± 1.75% to 15.35 ± 1.29% postoperatively (P <0.001).

CONCLUSIONS

Statistically significant improvements at MPV and PDW levels after surgery were noticed only at patients with excessive daytime sleepness whose ESS score was 10 or above. According to this, it would be preferable to operate these patients earlier to protect them from systemic effects.

Для цитирования: Sahin Murat S, Kizilirmak Deniz. Changes at Mean Platelet Volume and Platelet Distribution Width Levels After Septoplasty and Its Correlation With Epworth Sleepness Scale.. The Journal of craniofacial surgery. 2017. DOI: 10.1097/scs.0000000000003207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.