MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11605-008-0698-1

Медицинская библиотека · Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract · 2008

Magnetic augmentation of the lower esophageal sphincter: results of a feasibility clinical trial.

Bonavina Luigi, Saino Greta I, Bona Davide, Lipham John, Ganz Robert A, Dunn Daniel, DeMeester Tom

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

The high prevalence of gastroesophageal reflux disease continues to encourage the development of treatment modalities to fill the gap between acid-suppression therapy and the laparoscopic Nissen fundoplication. The Magnetic Sphincter Augmentation device has been designed to augment the lower esophageal sphincter barrier using magnetic force. A multi-center feasibility trial was done to evaluate safety and efficacy.

METHODS

Patients with typical heartburn (at least partially responding to proton-pump inhibitors), abnormal esophageal acid exposure, and normal esophageal peristalsis were enrolled. Patients with hiatal hernia >3 cm were excluded from the study. The device was implanted laparoscopically around the distal esophagus.

RESULTS

Over a 1-year period, 38 out of 41 enrolled patients underwent this procedure in 3 hospitals. No operative complications were recorded. A free diet was allowed since post-operative day one, and 97% of patients were discharged within 48 h. The mean follow-up was 209 days (range 12-434 days). The GERD-HRQL score decreased from 26.0 to 1.0 (p < 0.005). At 3 months post-operatively, 89% of patients were off anti-reflux medications, and 79% of patients had a normal 24-h pH test. All patients preserved the ability to belch. Mild dysphagia occurred in 45% of patients. No migrations or erosions of the device occurred.

CONCLUSIONS

Laparoscopic implant of the MSA device is safe and well tolerated. It requires minimal surgical dissection and a short learning curve compared to the conventional Nissen fundoplication.

Для цитирования: Bonavina Luigi, Saino Greta I, Bona Davide, Lipham John, Ganz Robert A, Dunn Daniel, DeMeester Tom. Magnetic augmentation of the lower esophageal sphincter: results of a feasibility clinical trial.. Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract. 2008. DOI: 10.1007/s11605-008-0698-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.