Медицинская библиотека · Biosensors & bioelectronics · 2015

Highly sensitive bacterial susceptibility test against penicillin using parylene-matrix chip.

Park Jong-Min, Kim Jo-Il, Song Hyun-Woo, Noh Joo-Yoon, Kang Min-Jung, Pyun Jae-Chul

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This work presented a highly sensitive bacterial antibiotic susceptibility test through β-lactamase assay using Parylene-matrix chip. β-lactamases (EC 3.5.2.6) are an important family of enzymes that confer resistance to β-lactam antibiotics by catalyzing the hydrolysis of these antibiotics. Here we present a highly sensitive assay to quantitate β-lactamase-mediated hydrolysis of penicillin into penicilloic acid. Typically, MALDI-TOF mass spectrometry has been used to quantitate low molecular weight analytes and to discriminate them from noise peaks of matrix fragments that occur at low m/z ratios (m/z<500). The β-lactamase assay for the Escherichia coli antibiotic susceptibility test was carried out using Parylene-matrix chip and MALDI-TOF mass spectrometry. The Parylene-matrix chip was successfully used to quantitate penicillin (m/z: [PEN+H](+)=335.1 and [PEN+Na](+)=357.8) and penicilloic acid (m/z: [PA+H](+)=353.1) in a β-lactamase assay with minimal interference of low molecular weight noise peaks. The β-lactamase assay was carried out with an antibiotic-resistant E. coli strain and an antibiotic-susceptible E. coli strain, revealing that the minimum number of E. coli cells required to screen for antibiotic resistance was 1000 cells for the MALDI-TOF mass spectrometry/Parylene-matrix chip assay.

Для цитирования: Park Jong-Min, Kim Jo-Il, Song Hyun-Woo, Noh Joo-Yoon, Kang Min-Jung, Pyun Jae-Chul. Highly sensitive bacterial susceptibility test against penicillin using parylene-matrix chip.. Biosensors & bioelectronics. 2015. DOI: 10.1016/j.bios.2015.04.059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.