MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ca.21083

Медицинская библиотека · Clinical anatomy (New York, N.Y.) · 2010

Brachialis insertion measurement: an anatomic cadaver study for plate fixation of the coronoid process fracture.

Ma Jun-Feng, Chang Shi-Min

СтатьяПеревод в очереди

Аннотация

Detailed assessment of the proximity of the brachialis insertion to the anterior bundle of the medial collateral ligament and its potential influence on plate application for the treatment of the coronoid process fracture has not been reported previously. The purpose of this study was to describe the anatomic interval used for coronoid plate and the measurement of the brachialis insertion to confirm partial release of the insertion site may be required during plate fixation of the coronoid process fracture. After eight fresh-frozen cadaveric elbows were dissected, the interval between the brachialis insertion and the attachment of the anterior bundle of medial collateral ligament was identified, and the gross morphological characteristics of the brachialis insertion were also recorded. The average width of the interval was 4.14 mm, and the brachialis was found to be consisted of a superficial head and a deep head, and insertion of the deep head was composed of three units: a medial aponeurosis, a lateral aponeurosis, and muscle fibers inserted directly into the ulna. The interval between the brachialis insertion and the attachment of the anterior bundle of medial collateral ligament can be used for placement of the coronoid plate regardless of the plate type. Partial release of the brachialis insertion is necessary during the operation, while the width of the plate is larger than that of the interval. This study may provide some useful information on plate application for the treatment of the coronoid process fracture.

Для цитирования: Ma Jun-Feng, Chang Shi-Min. Brachialis insertion measurement: an anatomic cadaver study for plate fixation of the coronoid process fracture.. Clinical anatomy (New York, N.Y.). 2010. DOI: 10.1002/ca.21083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.