MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aogs.13394

Медицинская библиотека · Acta obstetricia et gynecologica Scandinavica · 2018

Customized fetal growth standard compared with the INTERGROWTH-21st century standard at predicting small-for-gestational-age neonates.

Odibo Anthony O, Nwabuobi Chinedu, Odibo Linda, Leavitt Karla, Obican Sarah, Tuuli Methodius G

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

The INTERGROWTH-21st project (IG-21) was recently performed aiming to provide a universal benchmark for comparing fetal growth across different ethnicities. Our aim was to compare the IG-21 with a customized standard for predicting pregnancies at risk for neonatal small-for-gestational age (SGA) and adverse outcomes.

MATERIAL AND

METHODS

This was a prospective cohort study including singleton pregnancies presenting for fetal growth assessment between 26 and 36 weeks of gestation. Fetal growth restriction was defined as estimated fetal weight <10th centile for gestational age using IG-21 and a customized standard. Neonatal SGA was defined as birthweight <10th centile for gestational age by the Alexander chart. Primary outcome was the prediction of neonatal SGA. Secondary outcomes included a composite of adverse neonatal outcomes. The discriminatory ability of each growth standard was compared using area under receiver operating characteristic curves (AUC).

RESULTS

Of 1054 pregnancies meeting the inclusion criteria, the incidence of neonatal SGA was 139 (13.2%), and a composite adverse neonatal outcome occurred in 300 (28.4%). The sensitivity of the customized standard (38.8%) was higher than that of IG-21 (24.5%) for predicting neonatal SGA, with AUC (95% CI) of 0.67 (0.63-0.71) for customized vs 0.62 (0.58-0.65) for IG-21; P = .003. Both standards were comparable in predicting the composite adverse neonatal outcomes: AUC (95% CI) 0.52 (0.50-0.55) for customized vs 0.51 (0.50-0.53) for IG-21; P = 0.25.

CONCLUSIONS

Both growth standards had modest performance in detecting neonatal SGA and were poor at predicting short-term adverse neonatal outcome.

Для цитирования: Odibo Anthony O, Nwabuobi Chinedu, Odibo Linda, Leavitt Karla, Obican Sarah, Tuuli Methodius G. Customized fetal growth standard compared with the INTERGROWTH-21st century standard at predicting small-for-gestational-age neonates.. Acta obstetricia et gynecologica Scandinavica. 2018. DOI: 10.1111/aogs.13394.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.