MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jim.2019.01.004

Медицинская библиотека · Journal of immunological methods · 2019

Reducing the risk of misdiagnosis of indirect ELISA by normalizing serum-specific background noise: The example of detecting anti-FGFR3 autoantibodies.

Moritz Christian P, Tholance Yannick, Lassablière François, Camdessanché Jean-Philippe, Antoine Jean-Christophe

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Indirect enzyme-linked immunosorbent assay (ELISA) is an important diagnostic method as it enables the quantification of the presence of autoantibodies in human blood sera. However, unspecific binding of antibodies to the solid phase causes considerable serum-specific background noise (SSBN), involving the risk of false positive diagnosis. Therefore, we present a simple and concise, yet obvious proof-of-principle of a recently suggested normalization method. The method is based on subtracting SSBN by using non-coated ELISA wells as a control for each serum-of-interest. We performed ELISA to quantify anti-fibroblast growth factor receptor 3 (FGFR3) antibody levels in three positive controls (two anti-FGFR3-positive patients and a rabbit antiserum against FGFR3) and 58 negative controls (healthy blood donors). In all subjects, we found considerable unspecific reactivity which strongly varied among subjects. The conventional normalization method was not able to balance this strong SSBN, as demonstrated by 2/58 false positive healthy controls and one FGFR3-positive patient that was hidden in the noise (false negative). SSBN normalization reduced the frequency of false-positives to 0/58. Further, all three anti-FGFR3-positive sera were successfully detected and even doubled their z-score used to determine positivity. Albeit occupying more space on the ELISA plate, we strongly recommend considering this normalization method when working with blood sera. To better put the idea across to the community, we depict the SSBN issue and its solution in a graphic scheme. We conclude that SSBN normalization increases the sensitivity and specificity of indirect ELISA and thereby reduces the risk of false positive and false negative diagnosis. © 2019. Licensed under the Creative Commons [CC BY-NC 4.0 licence, https://doi.org/10.1016/j.jim.2019.01.004].

Для цитирования: Moritz Christian P, Tholance Yannick, Lassablière François, Camdessanché Jean-Philippe, Antoine Jean-Christophe. Reducing the risk of misdiagnosis of indirect ELISA by normalizing serum-specific background noise: The example of detecting anti-FGFR3 autoantibodies.. Journal of immunological methods. 2019. DOI: 10.1016/j.jim.2019.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.