MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1172/jci.insight.120178

Медицинская библиотека · JCI insight · 2018

Fully automated, real-time 3D ultrasound segmentation to estimate first trimester placental volume using deep learning.

Looney Pádraig, Stevenson Gordon N, Nicolaides Kypros H, Plasencia Walter, Molloholli Malid, Natsis Stavros, Collins Sally L

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАVideo-Audio MediaПеревод в очереди

Аннотация

We present a new technique to fully automate the segmentation of an organ from 3D ultrasound (3D-US) volumes, using the placenta as the target organ. Image analysis tools to estimate organ volume do exist but are too time consuming and operator dependant. Fully automating the segmentation process would potentially allow the use of placental volume to screen for increased risk of pregnancy complications. The placenta was segmented from 2,393 first trimester 3D-US volumes using a semiautomated technique. This was quality controlled by three operators to produce the "ground-truth" data set. A fully convolutional neural network (OxNNet) was trained using this ground-truth data set to automatically segment the placenta. OxNNet delivered state-of-the-art automatic segmentation. The effect of training set size on the performance of OxNNet demonstrated the need for large data sets. The clinical utility of placental volume was tested by looking at predictions of small-for-gestational-age babies at term. The receiver-operating characteristics curves demonstrated almost identical results between OxNNet and the ground-truth). Our results demonstrated good similarity to the ground-truth and almost identical clinical results for the prediction of SGA.

Для цитирования: Looney Pádraig, Stevenson Gordon N, Nicolaides Kypros H, Plasencia Walter, Molloholli Malid, Natsis Stavros, Collins Sally L. Fully automated, real-time 3D ultrasound segmentation to estimate first trimester placental volume using deep learning.. JCI insight. 2018. DOI: 10.1172/jci.insight.120178.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.