Automated Quantitative Computed Tomography Versus Visual Computed Tomography Scoring in Idiopathic Pulmonary Fibrosis: Validation Against Pulmonary Function.

Jacob Joseph, Bartholmai Brian J, Rajagopalan Srinivasan, Kokosi Maria, Nair Arjun, Karwoski Ronald, Raghunath Sushravya M, Walsh Simon L F, Wells Athol U, Hansell David M

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: The aim of the study was to determine whether a novel computed tomography (CT) postprocessing software technique (CALIPER) is superior to visual CT scoring as judged by functional correlations in idiopathic pulmonary fibrosis (IPF).

MATERIALS AND

METHODS

A total of 283 consecutive patients with IPF had CT parenchymal patterns evaluated quantitatively with CALIPER and by visual scoring. These 2 techniques were evaluated against: forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), diffusing capacity for carbon monoxide (DLco), carbon monoxide transfer coefficient (Kco), and a composite physiological index (CPI), with regard to extent of interstitial lung disease (ILD), extent of emphysema, and pulmonary vascular abnormalities.

RESULTS

CALIPER-derived estimates of ILD extent demonstrated stronger univariate correlations than visual scores for most pulmonary function tests (PFTs): (FEV1: CALIPER R=0.29, visual R=0.18; FVC: CALIPER R=0.41, visual R=0.27; DLco: CALIPER R=0.31, visual R=0.35; CPI: CALIPER R=0.48, visual R=0.44). Correlations between CT measures of emphysema extent and PFTs were weak and did not differ significantly between CALIPER and visual scoring. Intriguingly, the pulmonary vessel volume provided similar correlations to total ILD extent scored by CALIPER for FVC, DLco, and CPI (FVC: R=0.45; DLco: R=0.34; CPI: R=0.53).

CONCLUSIONS

CALIPER was superior to visual scoring as validated by functional correlations with PFTs. The pulmonary vessel volume, a novel CALIPER CT parameter with no visual scoring equivalent, has the potential to be a CT feature in the assessment of patients with IPF and requires further exploration.

Для цитирования: Jacob Joseph, Bartholmai Brian J, Rajagopalan Srinivasan, Kokosi Maria, Nair Arjun, Karwoski Ronald, Raghunath Sushravya M, Walsh Simon L F, Wells Athol U, Hansell David M. Automated Quantitative Computed Tomography Versus Visual Computed Tomography Scoring in Idiopathic Pulmonary Fibrosis: Validation Against Pulmonary Function.. Journal of thoracic imaging. 2016. DOI: 10.1097/rti.0000000000000220.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.