MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jssc.201401032

Медицинская библиотека · Journal of separation science · 2014

Determination of tetracycline antibiotics in fatty food samples by selective pressurized liquid extraction coupled with high-performance liquid chromatography and tandem mass spectrometry.

Jiao Zhe, Zhang Suling, Chen Hongwei

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

For the determination of trace residues of tetracycline antibiotics in fatty food samples, selective pressurized liquid extraction coupled with high-performance liquid chromatography and tandem mass spectrometry was applied in this study. Copper(II) isonicotinate was first used as online cleanup adsorbent in the selective pressurized liquid extraction process. The adsorbent to sample ratio, extraction temperature, extraction time, and recycle times, etc. were optimized. The tetracyclines in food samples of pork, chicken meat, and clam meat were detected by liquid chromatography with tandem mass spectrometry. Tetracycline was found at levels of 0.32 and 0.53 μg/g and oxytetracycline was found at 0.14 and 0.21 μg/g in chicken meat and clam meat, respectively, while chlorotetracycline and deoxytetracycline were below the detection limit. The detection limit (S/N = 3) for these four tetracyclines were from 0.2 to 3.3 ng/g, the recoveries were from 75.8 to 110.5%, and relative standard deviations were from 5.5 to 13.6%. Copper(II) isonicotinate showed a higher purification capacity than other cleanup adsorbents for extraction of antibiotics in fatty food and the recovery showed predominance compared with a pressurized liquid extraction method without adsorbent. The study demonstrated that copper(II) isonicotinate would be a promising cleanup adsorbent in pressurized liquid extraction for the analysis of trace organic pollutants in complicated samples.

Для цитирования: Jiao Zhe, Zhang Suling, Chen Hongwei. Determination of tetracycline antibiotics in fatty food samples by selective pressurized liquid extraction coupled with high-performance liquid chromatography and tandem mass spectrometry.. Journal of separation science. 2014. DOI: 10.1002/jssc.201401032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.