Improvement of the optical cavity-based biosensor's limit of detection using optimal 3-aminopropyltriethoxysilane process.

Sypabekova Marzhan, Kleiss Jenna, Hagemann Aidan, Schuemann Sophia, Wills Riley, Zechmann Bernd, Kim Seunghyun

СтатьяПеревод в очереди

Аннотация

Optical resonator-based biosensors are important for advancing medical diagnostics and environmental monitoring due to their high sensitivity and label-free detection capabilities. In this study, we present a systematic comparison of three 3-aminopropyltriethoxysilane (APTES) functionalization methods - ethanol-based, methanol-based, and vapor-phase - on an Optical Cavity-based Biosensor (OCB) designed to detect streptavidin. The APTES process is an important first step for surface functionalization to form a linker to immobilize receptor molecules on the sensor surface. Our aim was to identify the deposition conditions that yield a uniform APTES layer, with an enhanced bioreceptor immobilization and improved sensor performance. By using a differential detection approach using two laser diodes at 808 nm and 880 nm, we achieved real-time intensity measurements in the OCB that enabled sensitive detection of target analyte. Among the three APTES methods tested, the methanol-based protocol (0.095% APTES) led to a significantly improved limit of detection (LOD) of 27 ng/mL, a threefold improvement over our previous results. Detailed atomic force microscopy (AFM), contact angle, and dose-response analyses confirmed the high quality of the monolayer formed under optimal conditions, emphasizing the importance of solvent choice and controlled deposition parameters for obtaining stable functional layers. These findings emphasize how the improved APTES functionalization directly enhances the sensitivity and reliability of our OCB system, offering a robust and adaptable approach for real-time, label-free detection in diverse biosensing applications.

Для цитирования: Sypabekova Marzhan, Kleiss Jenna, Hagemann Aidan, Schuemann Sophia, Wills Riley, Zechmann Bernd, Kim Seunghyun. Improvement of the optical cavity-based biosensor's limit of detection using optimal 3-aminopropyltriethoxysilane process.. Scientific reports. 2025. DOI: 10.1038/s41598-025-92151-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.